Applications
- FTTx networks
- Indoor / Outdoor
- Suitable for underground duct installations
Features
- Single jacket with ripcords for easy stripping
- Contains non-metallic strength member
- PE Jacket 			
°
| Mechanical Specifications | |||||||||
| Fiber Count | 12 - 48 | 72 | 96 | 144 | 288 | 432  | 432  | 576  | 864  | 
| Fibers per Tube | 12 | 24  | |||||||
| Nominal Outer Diameter | 10.2 mm (0.40 in)  | 11.0 mm (0.43 in)  | 12.3 mm (0.48 in)  | 15.6 mm (0.61 in)  | 18.6 mm (0.73 in)  | 21.3 mm (0.84 in)  | 18.5 mm (0.73 in)  | 21.3 mm (0.84 in)  | 24.4 mm (0.96 in)  | 
| Max. Tensile Strength, Long-Term | 620 N (139 lb)  | 860 N (193 lb)  | |||||||
| Max. Tensile Strength, Short-Term | 1800 N (405 lb)  | 2500 N (562 lb)  | |||||||
| Min. Bend Radius Installation | 20 times x cable O.D. | ||||||||
| Min. Bend Radius Operation | 10 times x cable O.D.  | ||||||||
| Cable Design | ||||||||
| Fiber Count | 12 - 48 | 72 | 96 | 144 | 288 | 432 | 576  | 864  | 
| Fiber Color | Blue, Orange, Green, Brown, Slate, White, Red, Black, Yellow, Violet, Pink, Aqua | |||||||
| Tube Color Coding | Blue, Orange, Green, Brown, Slate, White, Red, Black, Yellow, Violet, Pink, Aqua | |||||||
| Outer Jacket Color | Black | |||||||
| Outer Jacket Material | Polyethylene(PE) | |||||||
| Fiber Coloring( l : Black Stripe Marking) | 
![]()  | 
| General Specification | |
| Environment | Indoor / Outdoor | 
| Cable Type | Gel-free Tube | 
| Fiber Type | Single-Mode(OS2) | 
| Application | Duct | 
| Standards | |
| RoHS | Free of hazardous substances according to RoHS 2011/65/EU | 
| Standards | IEC60794 : Basic requirements for optical fiber and cable elements ANSI/ICEA S-87-640 : Standard for optical fiber outside plant communications cable  | 
| Design and Test Criteria | ANSI/ICEA S-87-640 | 
| Ordering Information | |||||||||
| Fiber Count | 12 - 48 | 72 | 96 | 144 | 288 | 432 (12F) | 432 (24F)  | 576  | 864  | 
| Weight | 70 kg/km (47 lb/1,000ft)  | 84 kg/km (56 lb/1,000ft)  | 103 kg/km (69 lb/1,000ft)  | 165 kg/km (111 lb/1,000ft)  | 217 kg/km (146 lb/1,000ft)  | 271 kg/km (182 lb/1,000ft)  | 216 kg/km (145 lb/1,000ft)  | 261 kg/km (175 lb/1,000ft)  | 324 kg/km (218 lb/1,000ft)  | 
| Container Loading Capacity (40ft Container)  | 98 km (320,000 ft)  | 98 km (320,000 ft)  | 85 km (280,000 ft)  | 79 km (260,000 ft)  | 67 km (220,000 ft)  | 55 km (180,000 ft)  | 55 km (180,000 ft)  | 55 km (180,000 ft)  | Requires discussion  | 
| Length / Reel | 6.096 km (20,000 ft) | ||||||||
| Environmental Conditions | |
| Temperature Range, Installation | - 30 °C to +70 °C (-22 °F to 158 °F) | 
| Temperature Range, Storage | - 40 °C to +70 °C (-40 °F to 158 °F) | 
| Temperature Range, Operation | - 40 °C to +70 °C (-40 °F to 158 °F) | 
| Optical Characteristics (Single-mode) | |
| Fiber Category | G.652.D | 
| Attenuation after cable | 0.36 dB/km / 0.36 dB/km / 0.25 dB/km | 
| Wavelengths | 1310 nm / 1383 nm / 1550 nm | 
Datasheet download  | Duct (Dry) Cable Datasheet |