Application
- FTTX networks
- Aerial or Duct
- Indoor and Outdoor application
- Subscriber network system and Long haul communication system
Features
- Easy installation
- Excellent mechanical and environmental characteristics - Available in pre-connectorized assemblies
- Dielectric structure
| Mechanical Specifications | |
| Max. Tensile Strength | 1350 N (303 lb) |
| Min. Bend Radius Installation | 20 times x cable O.D. |
| Min. Bend Radius Operation | 10 times x cable O.D. |
| Nominal Outer Diameter | 4.3 mm x 8.0 mm (0.17 in x 0.31 in) |
Cable Design | |
| Fibers per Tube | Up to 2 |
| Fiber Count | Up to 2 |
| Inner Jacket Color | Natural |
| Outer Jacket Color | Black |
| Outer Jacket Material | Polyethylene (PE) |
| General Specifications | |
| Application | Drop cables |
| Tube Type | Dry |
| Fiber Type | Single-Mode (OS2) |
| Fiber & Tight Buffer Coloring( l : Black Dot Marking) |
![]() |
| Ordering Information | |
| Weight | 37 kg/km (25 lb / 1,000 ft) |
| Length / Reel | 4 km (13,000 ft) without pallet |
| Standards | |
| RoHS | Free of hazardous substances according to RoHS 2011/65/EU |
| Standards | IEC 60794: Basic requirements for optical fiber and cable elements ANSI/ICEA S-87-640: Standard for optical fiber outside plant communications cable |
| Environmental Conditions | |
| Temperature Range, Installation | - 10°C to +40°C (14°F to 104°F) |
| Temperature Range, Storage | - 30°C to +60°C (-22°F to 140°F) |
| Temperature Range, Operation | - 30°C to +60°C (-22°F to 140°F) |
| Optical Characteristics (Single-mode) | |
| Fiber Category | G.652.D / G.657.A1 |
| Attenuation after cable | 0.35 dB/km / 0.35 dB/km / 0.25 dB/km |
| Wavelengths | 1310 nm / 1383 nm / 1550 nm |
Datasheet download | Non-Toneable Flat Drop Cable T/B |